Measures the charging & discharging state of the battery.
It’s essentially the ‘Fuel Gauge for the Battery’ & informs of all current data of the battery.
- Nominal battery voltage: 12V / 24V / 48V
- Shunt: 100A/200A/400A
- Compatible with AGM, Lead acid, Lithium, and Gel batteries
- Minimum battery capacity 50Ah
- 3 Years Warranty
How much residual charge does my board battery have? Is the battery state really "Full"? Why is energy taken from the battery, although the consumers have been switched off? The VOTRONIC LCD Battery Computer S answers these questions - exactly to percentage (%) an ampere-hour (Ah). At the touch of a button, it provides comprehensive information on the instantaneous charging state of the battery, the flowing battery current rates, and the battery's voltage.
Since the unit is permanently in contact with "its battery", it records and evaluates all battery actions. All charging and discharging currents are counted accurately. Battery size, self-discharge, battery load, etc., are considered by programmed characteristic diagrams. Even the slightest leakage current is detected and recorded.
The residual capacity of the battery is calculated from the measured values and the battery size. The result is a correct indication of the charging state (of the capacity, which is still available, the residual charge) of the board battery as a numerical value in Ampere-hours ("Ah") and as a percentage ("%") as well as in the form of a clear level bar, such as it is known from a fuel gauge. The LCD Battery Computer S is suitable for all battery types (acid, gel, AGM, lithium adjustable) with 12 V and 24 V battery voltage.
Of course, the instantaneous battery voltage ("V") and the instantaneous battery current ("A") are also displayed. A minus sign identifies discharge current rates (consumers). Furthermore, the discharge current rates are marked with a well-legible sign "Charge". Apart from that, there is a further display possibility for the voltage of a second battery, such as controlling the vehicle’s starter battery.
Functions
- Battery voltage board battery, 7 to 32 V (Volts), measuring scale 0.1 V.
It allows for the conclusion of the battery behaviour in case of variations in load. It serves as an operational check,
- for instance, of the charger, the solar system, the dynamo, etc. Flashing warning signal in case of overvoltage.
- Battery current (+ = charge/- = discharge +/- to max. +/ -1800 A (Amperes, depending on the type) measuring scale
0.1 A, control of the discharge current rates (load) by the consumers, indicated by the sign "-".
Control of the discharge current rates identified by a "Charge" sign.
- Battery capacity "Ah" (residual charge in Ampere-hours) from 0 Ah (empty) to nominal capacity (full), max. 2000 Ah.
- Battery capacity "%" (percentage residual charge) from 0 % (empty) to nominal capacity (full), 100 %.
- Battery voltage starter battery, 2nd battery, 7 to 32 V (Volts), measuring scale 0.1 V.
- Terminal, freely programmable and tactile (PNP, plus potential 12 V / 24 V, max. 0.5 A).
Note: The units are adapted to the measuring shunts included in the delivery. They cannot be
operated in connection with other measuring shunts or exchanged by each other!
- CE, E-Test (EMV/Automotive Regulations)
- Package content Display unit, measuring shunt 100 A, 200 A or 400 A, connection cable of 5 m length, ground strap, fastening screws, manual, drilling jig.
Features
A microprocessor control measures, calculates and displays the following values:
- Instantaneous solar power 0 – 999 W (Watt)
- Instantaneous solar current 0 – 60,0 A (Ampere)
Any geographic or atmospheric influences will be displayed immediately and unmistakable.
The same applies to the exposure of the sun, partial shading or soiling of the solar modules.
- Instantaneous voltage of the solar battery 7 – 32,0 V (Volt)
Allows conclusions concerning the battery state; flashing warning signal in case of undervoltage and overvoltage of the battery.
- Charged solar capacity 0 – 9999 Ah (Ampere-hours)
- Charged solar energy 0 – 9999 kWh (Kilowatt-hours)
The power (Wh and kWh) being generated by the solar modules and the capacity (Ah) being charged into the battery will be measured, added up and displayed, even over a longer period (days, weeks). If it is required for purposes of statistics, each of the display units can be reset to “zero” at any time
We are liable for material defects of all our products within 36 months from the purchase date against the representation of the sales slip or the invoice, proper handling, intended use and consideration of the installation and operating manual provided. If the buyer or third execute modification and repair tasks to the product (external intervention) or will the electronic or the entire product damaged by moisture, any claims for defects for these tasks and the results being involved will be void. Claims will also be void for any service performed by a third we have not ordered in writing.